KM Commands for KM Settings

Home  Previous  Next

Alert Actions: Enables you to select the Alert Actions i.e. different notification methods to be executed by Hardware Sentry when a parameter breaches its threshold.

KMCmd_Set_Alert_Action

KM Commands — Setting Alert Actions

Threshold Mechanism Selection: Allows you to select the threshold mechanism to be used

KMCmd_Threshold_Mechanism

KM Commands — Threshold Mechanism Selection

Automatic (by default): Hardware Sentry determines the mode of threshold management best suited to the system. The different modes are:

Tuning: Hardware Sentry uses the internal PATROL mechanism to set thresholds
Event Management: Hardware Sentry automatically sets thresholds through Event Management
No Thresholds: Hardware Sentry does not set any thresholds and lets you specify them manually

Missing Device Detection: Allows you to disable the missing device detection feature. By default, Hardware Sentry detects "missing devices" i.e. devices previously monitored but which have disappeared during the monitoring or after a reboot or due to some other cause

KMCmd_Missing_Device_Detection

KM Commands — Missing Device Detection

Intrusion Detection Alerts: Allows you to decide when an intrusion detection alert for the enclosure/ systems chassis should be raised

KMCmd_Intrusion_Detection

KM Commands — Intrusion Detection Settings

The IntrusionStatus parameter of each enclosure object discovered by Hardware Sentry reports whether or not the chassis has been opened, and triggers an alarm as per user settings.

Network Link Alerts: Allows you to choose the monitoring/alert settings for the network link status

KMCmd_Network_Link_Monitoring

KM Commands — Network Link Monitoring Settings

Internal KM Issues Notification: Allows you to enable/disable and select the type of information messages displayed by Hardware Sentry in the system output window of the PATROL Console

KMCmd_Internal_Message

KM Commands — Internal Message Notification

Unknown Status Management: Allows you to select the actions to be performed if Hardware Sentry returns an "Unknown" status when it is unable to detect a device or sensor

KMCmd_Unknown_Status_Mgt

KM Commands — Unknown Status Management

Discovery Interval: Enables you to customize the discovery cycle. By default, discovery is performed every hour

KMCmd_Discovery_Cycle

KM Commands — Discovery Cycle Customization

Polling Interval: Enables you to customize the polling cycle. By default, the polling interval is done every two minutes.

KMCmd_Polling_Interval

KM Commands — Polling Interval Customization

Additional Settings: Allow you to:

Restore Device or Sensor Monitoring: Brings up the Restore Device or Sensor Monitoring wizard to restore one or several objects after their monitoring has been stopped (if removed)
Display Settings for UNIX Consoles: Gives you the option to turn on the UNIX console mode and modify all object labels to fit the PATROL UNIX Console label size
Enable Debug Mode: Activates or deactivates the Debug mode. The debug mode displays debug messages in the PATROL System Output Window or saves it in a file if you enter the file path.

See Also

Hardware Sentry Menu Commands

MS_HW_MAIN