Brocade SAN Switch

Home  Previous  Next

This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol and supports the Brocade MIB (fcSwitch-MIB).

Target

Typical platform(s): SAN Switches

Operating system(s): Storage Device

Instrumentation layer: Brocade SNMP Agent (fcSwitch)

Technology used: SNMP

Discovered objects

Fans (SEN_HW_FAN)

Temperature sensors (SEN_HW_TEMPERATURE)

Power supplies (SEN_HW_POWERSUPPLY)

Network cards (SEN_HW_NETWORK)

Enclosure model (SEN_HW_ENCLOSURE)

Collected Parameters

SEN_HW_FAN / Status

SEN_HW_FAN / Speed

SEN_HW_TEMPERATURE / Status

SEN_HW_TEMPERATURE / Temperature

SEN_HW_POWERSUPPLY / Status

SEN_HW_NETWORK / Status

SEN_HW_NETWORK / LinkStatus

SEN_HW_NETWORK / LinkSpeed

SEN_HW_NETWORK / ErrorCount

SEN_HW_NETWORK / TransmittedPacketsRate

SEN_HW_NETWORK / ReceivedPacketsRate

SEN_HW_NETWORK / TransmittedBytesRate

SEN_HW_NETWORK / ReceivedBytesRate

Note        This connector is able to monitor the local host and/or a remote system.


See Also

Platforms & Connectors