Access Rights
|
Text
|
On UNIX/Linux systems: Parameter displays the access rights to the monitored file in the form: “rwxrwxrwx”
On Windows system: Parameter is not available. The message “No data” is displayed.
|
Alarm or Warning
Alarm
No default thresholds or alerts set
|
Exists
|
Text
|
Parameter that reflects whether or not the monitored file is currently present.
The parameter’s value is either “True” or “False”.
|
Alarm or Warning
Alarm
Alarm activated by default
|
Group
|
Text
|
On UNIX/Linux: Parameter displays the owner group of the file.
On Windows systems: Parameter is not available. The message “No data” is displayed.
|
Alarm or Warning
Alarm
No default thresholds or alerts set
|
Growth Percentage
|
Numeric
|
Parameter displays the growth of the monitored file relative to its previous size in percentage.
The parameter’s value is calculated as follows:
Unit: KB/min (Kilobytes per minute)
Note: The value can be negative when the file shrinks in size.
|
Alarm or Warning
Alarm
No default thresholds or alerts set
|
Growth Speed
|
Numeric
|
Parameter displays the growth of the monitored file calculated as follows:
Unit: KB/min (Kilobytes per minute)
Note: The value can be negative when the file shrinks in size.
|
Alarm or Warning
Alarm
No default thresholds or alerts set
|
Last Modified
|
Text
|
Parameter displays the full path of the currently monitored file.
Note: This parameter allows you to easily identify which file is monitored when wildcards have been used in the field for “name” of file to be monitored.
|
Alarm or Warning
Alarm
No default thresholds or alerts set
|
Monitored File
|
Text
|
Parameter displays the full path of the currently monitored file.
Note: This parameter allows you to easily identify which file is monitored when wildcards have been used in the field for “name” of file to be monitored.
|
Alarm or Warning
Alarm
No default thresholds or alerts set
|
Owner
|
Text
|
On UNIX/Linux systems: Parameter displays the owner of the file.
On Windows: Parameter is not available. The message “No data” is displayed.
|
Alarm or Warning
Alarm
No default thresholds or alerts set
|
Size
|
Numeric
|
Parameter displays the size of the monitored file.
Unit: KB (Kilobytes)
|
Alarm or Warning
Alarm
No default thresholds or alerts set
|