Bandwidth Utilization
|
Percentage used of the available bandwidth.
|
Percentage (%)
|
None
|
Configured Speed
|
Speed configured for this adapter.
Possible values: "auto", "1 Gb/s", "2 Gb/s", "4 Gb/s", "8 Gb/s", "10 Gb/s".
|
Gigabits per second (Gb/s)
|
None
|
Connected Initiators Count
|
Total number of initiators (hosts) connected to this port (target adapter).
|
initiators
|
None
|
CRC Error Rate
|
CRC errors per second.
|
errors/s
|
None
|
Discarded Frame Rate
|
Number of frames discarded per second.
|
frames/s
|
None
|
Established Connection
|
Type of connection established.
Possible values: "ptp" or "loop".
|
n/a
|
None
|
FCP Protocol Error Rate
|
FCP protocol errors per second.
|
errors/s
|
None
|
Firmware Revision
|
Firmware revision of the adapter.
|
n/a
|
None
|
Hardware Description
|
Description of the adapter (vendor and model).
|
n/a
|
None
|
Inbound Bandwidth Utilization
|
Percentage of inbound bandwidth used on the FC link (received bytes).
|
Percentage (%)
|
None
|
Link Speed
|
Actual speed of the FC port.
|
Gigabits per second (Gb/s)
|
None
|
Link Status
|
Indicates whether the link is up or down.
|
(0 = Plugged; 1 = Unplugged)
|
1 = Warning
|
Operation Rate*
|
Total number of operations per second.
|
operations/s
|
None
|
Other Operation Rate
|
Total number of other operations per second.
|
operations/s
|
None
|
Outbound Bandwidth Utilization
|
Percentage of outband bandwidth used on the FC link (sent bytes).
|
Percentage (%)
|
None
|
Packet Size
|
FC packet size of adapter.
|
Bytes (B)
|
None
|
Port Address
|
Host port address of the adapter.
|
n/a
|
None
|
Present
|
Indicates whether the device is still present or not since the last discovery. This parameter is updated at each discovery.
|
(0 = No; 1 = Yes)
|
0 = Alarm
|
Read Operation Rate
|
Number of read operations per second.
|
operations/s
|
None
|
Received Byte Rate
|
Bytes received per second.
|
Megabytes per second (MB/s)
|
None
|
Received Bytes
|
Bytes received since the last collect.
|
Gigabytes (GB)
|
None
|
Revision
|
Revision for the optical transceiver.
|
n/a
|
None
|
Sent Byte Rate
|
Bytes sent per second.
|
Megabytes per second (MB/s)
|
None
|
Sent Bytes
|
Bytes sent since the last collect.
|
Gigabytes (GB)
|
None
|
Speed Capabilities
|
FC speed capabilities for the optical transceiver.
Possible values: "1", "2", "4", "8" in Gb/s.
|
Gigabits per second (Gb/s)
|
None
|
StandBy
|
Indicates whether the adapter is on standby.
|
n/a
|
None
|
Status Information
|
Detailed information about the adapter status.
|
n/a
|
None
|
Status
|
Status of the FC port.
|
(0 = OK; 1 = Degraded; 2 = Failed)
|
1 = Warning
2 = Alarm
|
Transfer Byte Rate*
|
Total bytes transferred per second (sent and received).
|
Megabytes per second (MB/s)
|
None
|
Transfer Bytes
|
Sent and received bytes since the last collect.
|
Gigabytes (GB)
|
None
|
Type
|
Type of the adapter.
Possible values: "physical", "local", "standby", "partner".
|
n/a
|
None
|
Write Operation Rate
|
Number of write operations per second.
|
operations/s
|
None
|
WWNN
|
FCP World Wide Node Name (WWNN) of the adapter.
|
n/a
|
None
|
WWPN
|
FCP World Wide Port Name (WWPN) of the adapter.
|
n/a
|
None
|