Volume

Home  Previous  Next

Parameters

Name

Description

Unit

Default Alert Conditions

Available Capacity Percentage

Percentage of capacity not consumed in the volume ( available data space).

Percentage (%)

None

Available Capacity

Total capacity not consumed in the volume.

Gigabytes (GB)

None

Capacity

Total usable capacity of the volume. It exposes the total data space and the snapshot reserve.

Gigabytes (GB)

None

CIFS Operation Rate

Total number of CIFS operations per second.

operations/s

None

CIFS Read Byte Rate

Bytes read per second via CIFS from the volume.

Megabytes per second (MB/s)

None

CIFS Read Bytes

Bytes read via CIFS from the volume since the last collect.

Gigabytes (GB)

None

CIFS Read Operation Rate

Number of read operations per second.

operations/s

None

CIFS Read Response Time

Average response time for read operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

CIFS Response Time

Average response time for all CIFS operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

CIFS Transfer Byte Rate

Total bytes read and written per second via CIFS to the volume.

Megabytes per second (MB/s)

None

CIFS Transfer Bytes

Read and written bytes via CIFS to the volume since the last collect.

Gigabytes (GB)

None

CIFS Write Byte Rate

Bytes written per second via CIFS to the volume since the last collect.

Megabytes per second (MB/s)

None

CIFS Write Bytes

Bytes written via CIFS to the volume since the last collect.

Gigabytes (GB)

None

CIFS Write Operation Rate

Number of write CIFS operations per second.

operations/s

None

CIFS Write Response Time

Average response time for CIFS write operations

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

Compression

Indicates the compression status.

(0 = No; 1 = Yes)

None

Consumed Capacity Percentage

Percentage of the capacity that is actually consumed in the volume. It exposes the consumed space compared to the capacity

Percentage (%)

None

Consumed Capacity

Number of bytes actually consumed in the volume. It exposes the data used space and the snapshot reserve.

Gigabytes (GB)

None

Containing Aggregate

The name of the aggregate in which the given flexible volume resides.

n/a

None

FCP Operation Rate

Total number of FCP operations per second.

operations/s

None

FCP Read Byte Rate

Bytes read per second via FCP from the volume since the last collect.

Megabytes per second (MB/s)

None

FCP Read Bytes

Bytes read via FCP from the volume since the last collect.

Gigabytes (GB)

None

FCP Read Operation Rate

Number of FCP read operations per second.

operations/s

None

FCP Read Response Time

Average response time for FCP read operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

FCP Response Time

Average response time for all FCP operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

FCP Transfer Byte Rate

Total bytes read and written per second via FCP to the volume.

Megabytes per second (MB/s)

None

FCP Transfer Bytes

Bytes read and written via FCP to the volume since the last collect.

Gigabytes (GB)

None

FCP Write Byte Rate

Bytes written per second via FCP to the volume since the last collect.

Megabytes per second (MB/s)

None

FCP Write Bytes

Bytes written via FCP to the volume since the last collect.

Gigabytes (GB)

None

FCP Write Operation Rate

Number of write FCP operations per second.

operations/s

None

FCP Write Response Time

Average response time for FCP write operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

FlexCache Read Byte Rate

Bytes read per second from the FlexCache since the last collect.

Megabytes per second (MB/s)

None

FlexCache Write Byte Rate

Bytes written  per second to the FlexCache since the last collect.

Megabytes per second (MB/s)

None

Inodes Used

Number of user-visible files (inodes) used. If the volume is restricted or offline, a value 0 returned.

inodes

None

Is Consistent

Indicates whether or not there is known inconsistency in the associated file system.

(0 = No; 1 = Yes)

None

Is Snaplock

Indicates whether or not this is a SnapLock volume.

(0 = No; 1 = Yes)

None

iSCSI Operation Rate

Total number of block protocol operations per second.

operations/s

None

iSCSI Read Byte Rate

Bytes read per second via block protocol from the volume since the last collect.

Megabytes per second (MB/s)

None

iSCSI Read Bytes

Bytes read via iSCSI from the volume since the last collect.

Gigabytes (GB)

None

iSCSI Read Operation Rate

Number of block protocol read operations per second.

operations/s

None

iSCSI Read Response Time

Average response time for block protocol read operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

iSCSI Response Time

Average response time for all block protocol operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

iSCSI Transfer Byte Rate

Total bytes read and written per second via iSCSI to the volume.

Megabytes per second (MB/s)

None

iSCSI Transfer Bytes

Bytes read and written via iSCSI to the volume since the last collect.

Gigabytes (GB)

None

iSCSI Write Byte Rate

Bytes written per second via iSCI to the volume since the last collect.

Megabytes per second (MB/s)

None

iSCSI Write Bytes

Bytes written via iSCSI to the volume since the last collect.

Gigabytes (GB)

None

iSCSI Write Operation Rate

Number of iSCI write operations per second.

operations/s

None

iSCSI Write Response Time

Average response time for iSCI write operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

Maximum Inode Count

Maximum number of user-visible files (inodes).

inodes

None

Mirror Status

Volume's mirror status.

(0 = OK; 1 = Degraded; 2 = Failed)

1 = Warning

2 = Alarm

NFS Operation Rate

Total number of NFS operations per second.

operations/s

None

NFS Read Byte Rate

Bytes read per second via NFS from the volume since the last collect.

Megabytes per second (MB/s)

None

NFS Read Bytes

Bytes read via NFS from the volume since the last collect.

Gigabytes (GB)

None

NFS Read Operation Rate

Number of NFS read operations per second.

operations/s

None

NFS Read Response Time

Average response time for NFS read operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

NFS Response Time

Average response time for all NFS operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

NFS Transfer Byte Rate

Total bytes read and written per second via NFS to the volume.

Megabytes per second (MB/s)

None

NFS Transfer Bytes

Read and written bytes via NFS to the volume since the last collect.

Gigabytes (GB)

None

NFS Write Byte Rate

Bytes written per second via NFS to the volume since the last collect.

Megabytes per second (MB/s)

None

NFS Write Bytes

Bytes written via NFS to the volume since the last collect.

Gigabytes (GB)

None

NFS Write Operation Rate

Number of write NFS operations per second.

operations/s

None

NFS Write Response Time

Average response time for NFS write operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

Operation Rate

Total number of operations per second.

operations/s

None

Owning vFiler

Name of the vFiler which owns this volume.

n/a

None

Quota Status

Quota state and percent initialized. 100% means that quotas are on, 0% means quotas are off, and anywhere in between means that quotas are initializing.

n/a

None

Read Byte Rate

Bytes read per second from the volume since the last collect.

Megabytes per second (MB/s)

None

Read Bytes

Bytes read from the volume since the last collect.

Gigabytes (GB)

None

Read Operation Rate

Number of read operations per second.

operations/s

None

Read Response Time

Average response time for read operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

Response Time*

Average response time for all operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

SAN Operation Rate

Total number of SAN operations per second

operations/s

None

SAN Read Byte Rate

Bytes read per second from the SAN since the last collect.

Megabytes per second (MB/s)

None

SAN Read Bytes

Bytes read via SAN from the volume since the last collect.

Gigabytes (GB)

None

SAN Read Operation Rate

Number of SAN read operations per second.

operations/s

None

SAN Read Response Time

Average response time for SAN read operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

SAN Response Time

Average response time for all SAN operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

SAN Transfer Byte Rate

Total bytes read and written per second via SAN to the volume.

Megabytes per second (MB/s)

None

SAN Transfer Bytes

Read and written bytes via SAN to the volume since the last collect.

Gigabytes (GB)

None

SAN Write Byte Rate

Bytes written per second via SAN to the volume since the last collect.

Megabytes per second (MB/s)

None

SAN Write Bytes

Bytes written via SAN to the volume since the last collect.

Gigabytes (GB)

None

SAN Write Operation Rate

Number of SAN write operations per second.

operations/s

None

SAN Write Response Time

Average response time for SAN write operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

Size

Total size of the volume including Snapshot reserve.

n/a

None

Snapshot Reserved Capacity Percentage

Percentage of disk space that has been set aside as reserved for snapshot usage.

Percentage (%)

None

Status Information

Detailed information about the volume status.

n/a

None

Status

Status of the volume.

(0 = OK; 1 = Degraded; 2 = Failed)

1 = Warning

2 = Alarm

Transfer Byte Rate*

Total bytes read and written per second to the volume.

Megabytes per second (MB/s)

None

Transfer Bytes

Read and written bytes to the volume since the last collect.

Gigabytes (GB)

None

Type

The type of the volume. Possible values are "Flexible" or "Traditional".

n/a

None

Used Inodes Percentage

Percentage of user-visible files (inodes) used.

Percentage (%)

None

UUID

Universal unique identifier (UUID) for the volume.

n/a

None

Write Byte Rate

Bytes written per second to the volume since the last collect.

Megabytes per second (MB/s)

None

Write Bytes

Bytes written to the volume since the last collect.

Gigabytes (GB)

None

Write Operation Rate

Number of write operations per second.

operations/s

None

Write Response Time

Average response time for write operations.

milliseconds (ms)

Warning = 30 to 100

Alarm > 100

* Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in BPPM