Available Capacity*
|
Total capacity not consumed in the storage center (unused raw space plus available capacity in disk folders).
|
Terabytes (TB)
|
None
|
Statistics
|
Back End Read Byte Rate
|
Read data traffic through the back-end port.
|
Megabytes per second (MB/s)
|
None
|
Statistics
|
Back End Read Operation Rate
|
Number of read operations through the back-end port.
|
Operations/s
|
None
|
Statistics
|
Back End Write Byte Rate
|
Bytes written per second to the storage center through the back-end port since the last collect.
|
Megabytes per second (MB/s)
|
None
|
Statistics
|
Back End Write Operation Rate
|
Number of write operations through the back-end port.
|
Operations/s
|
None
|
Statistics
|
Consumed Capacity Percentage
|
Percentage of the capacity that is actually consumed in the storage center.
|
Percentage (%)
|
None
|
Statistics
|
Consumed Capacity
|
Number of bytes actually consumed in the storage center.
|
Terabytes (TB)
|
None
|
Statistics
|
Front End Read Byte Rate
|
Read data traffic through the front-end port.
|
Megabytes per second (MB/s)
|
None
|
Statistics
|
Front End Read Operation Rate
|
Number of read operations through the front-end port.
|
Operations/s
|
None
|
Statistics
|
Front End Write Byte Rate
|
Bytes written per second to the storage center through the back-end port since the last collect.
|
Megabytes per second (MB/s)
|
None
|
Statistics
|
Front End Write Operation Rate
|
Number of write operations through the front-end port.
|
Operations/s
|
None
|
Statistics
|
Port Count
|
Number of ports on the Storage Center.
Note: This value can be used to know the number of required licenses for the monitoring system.
|
Ports
|
None
|
Statistics
|
Spare Disk Count
|
Number of unassigned disks, excluding the external disks, in the Storage Center.
Note: To avoid irrelevant alerts for a missing spare disk, a warning is only triggered on the Disk Folder class when the parameter value is equal to 0.
|
disks
|
None
|
Statistics
|
Status
|
Status of the Storage Center.
|
{0 = OK; 1 = Degraded; 2 = Failed}
|
Warning = 1
Alarm = 2
|
Availability
|
Subscribed Capacity Percentage
|
Ratio between the subscribed capacity and the disk folder capacity. Can exceed 100% for thin pools, therefore called oversubscribed.
|
Percentage (%)
|
None
|
Statistics
|
Subscribed Capacity
|
Sum of the host visible capacity for all volumes in the disk folder. Can be greater than the actual capacity of the storage pool for over-subscribed thin pools.
|
Terabytes (TB)
|
None
|
Statistics
|
Transfer Byte Rate 
|
Read and written data traffic (front end).
|
Megabytes per second (MB/s)
|
None
|
Statistics
|