Back to the list of connectors
DataDirect Networks (DDN) Storage Appliance (SNMP)
Connector file name: MS_HW_DDNSA.hdf
Description
This connector discovers the enclosure and the disks of DDN (DataDirect Networks) Storage Appliances as well as the various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.
Target
Typical platform: DataDirect Networks (DDN)
Operating system: Storage System
Prerequisites
Relies on: DDN SNMP Agent
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The DataDirect Networks (DDN) Storage Appliance (SNMP) connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.6894.2must return a value in the same subtree
Monitors
| Object Type | Discovered Properties | Collected Parameters |
|---|---|---|
| Enclosure (MS_HW_ENCLOSURE) |
|
|
| Fan (MS_HW_FAN) |
|
|
| Physical Disk (MS_HW_PHYSICALDISK) |
|
|
| Power Supply (MS_HW_POWERSUPPLY) |
|
|
| Temperature Sensor (MS_HW_TEMPERATURE) |
|
|