Back to the list of connectors
HP MSA 2000 & P2000
Connector file name: MS_HW_HPDotHill.hdf
This connector is superseded by:
This connector supersedes:
Description
This connector discovers the Environmental, Physical Disk, Logical Disk, Management Network Cards and Fibre Ports on P2000 / MSA Series Filers. We recommend setting the collection interval for all MSA Disk arrays to at least 15 minutes to prevent the management card from being overloaded.
Target
Typical platform: HP StorageWorks MSA P2000
Operating system: Storage System
Prerequisites
Relies on: HP MSA Management Card
Technology and protocols: SSH
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The HP MSA 2000 & P2000 connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:
- SSH is enabled on the monitored host
- The monitored host sends a prompt
- The connector sends
set cli-parameters pager off[Return] - The monitored host sends another prompt
- The connector sends
versions[Return] - The monitored host sends another prompt
- The connector sends
exit[Return] - The captured output contains
\(Storage Controller CPU Type\)\|\(Controller . Versions\)(regex)
Monitors
| Object Type | Discovered Properties | Collected Parameters |
|---|---|---|
| Enclosure (MS_HW_ENCLOSURE) |
|
|
| Blade (MS_HW_BLADE) |
|
|
| Fan (MS_HW_FAN) |
|
|
| Logical Disk, RAID (MS_HW_LOGICALDISK) |
|
|
| Network Card, FC Port (MS_HW_NETWORK) |
|
|
| Other Device (MS_HW_OTHERDEVICE) |
|
|
| Physical Disk (MS_HW_PHYSICALDISK) |
|
|
| Power Supply (MS_HW_POWERSUPPLY) |
|
|
| Temperature Sensor (MS_HW_TEMPERATURE) |
|
|
| Voltage Sensor (MS_HW_VOLTAGE) |
|
|