Back to the list of connectors
LSI sas2ircu Managed Raid Controllers
Connector file name: MS_HW_LSIsas2ircu.hdf
This connector supersedes:
Description
Gives physical disk and array status.
Target
Typical platform: Any system with LSI sas2ircu
Operating system: Linux
Prerequisites
Relies on: Sas2Ircu (LSI) managed RAID card
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
/opt/lsi/bin/sas2ircu
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the patrol account:
patrol ALL=(root) NOPASSWD: /opt/lsi/bin/sas2ircu
Connector Activation Criteria
The LSI sas2ircu Managed Raid Controllers connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:
- The command below succeeds on the monitored host
- Command:
/opt/lsi/bin/sas2ircu - Output contains:
SAS2IRCU: No command specified(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/opt/lsi/bin/sas2ircu LIST - Output contains:
^[0-9].*SAS.*:.*:.*:(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/bin/sh %EmbeddedFile(1)% - Output contains:
Device is a(regex)
- Command:
Monitors
| Object Type | Discovered Properties | Collected Parameters |
|---|---|---|
| Disk Controller (MS_HW_DISKCONTROLLER) |
|
|
| Logical Disk, RAID (MS_HW_LOGICALDISK) |
|
|
| Physical Disk (MS_HW_PHYSICALDISK) |
|
|