Description
This connector provides hardware monitoring for Nimble Storage Systems via Nimble's REST api
Target
Typical platform: Nimble
Operating system: Storage System
Prerequisites
Relies on: Nimble REST API
Technology and protocols: HTTP/REST
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The Nimble connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:
- Operating System is Storage System
- The HTTP Request below to the managed host succeeds:
- GET
/versions - Request Header:
Content-Type: application/json - The response body contains:
"name": "v1"(regex) - The HTTP Request below to the managed host succeeds:
- POST
/v1/tokens - Request Header:
Content-Type: application/json - Request Body:
{"data":{"password":"%{PASSWORD}","username":"%{USERNAME}"}} - The response body contains:
session_token(regex)
Monitors
Object Type Discovered Properties Collected Parameters Enclosure (MS_HW_ENCLOSURE) - Additional Information 1
- Additional Information 2
- Additional Information 3
- Model
- Serial Number
- Type
- Vendor
- Status
Blade (MS_HW_BLADE) - Blade Model
Fan (MS_HW_FAN) - Additional Information 1
- Speed
- Status
Network Card, FC Port (MS_HW_NETWORK) - Physical Address
- Physical Address Type
- Link Speed
- Link Status
- Status
Other Device (MS_HW_OTHERDEVICE) - Additional Information 1
- Type
- Status
Physical Disk (MS_HW_PHYSICALDISK) - Firmware Version
- Model
- Serial Number
- Size
- Type
- Vendor
- Status
Power Supply (MS_HW_POWERSUPPLY) - Additional Information 1
- Status
Temperature Sensor (MS_HW_TEMPERATURE) - Additional Information 1
- Status
- Temperature
- POST
- GET