Back to the list of connectors
Quantum (ADIC) Enterprise Level Tape Libraries
Connector file name: MS_HW_QuantumTapeLibraryi6000.hdf
This connector supersedes:
Description
This connector provides hardware monitoring through the Quantum Scalar's SNMP interface. It is primarily designed for the i2000 and i6000 libraries.
Target
Typical platforms: Quantum Scalar i2000, Quantum Scalar i6000
Operating system: Storage System
Prerequisites
Relies on: Quantum SNMP Agent (ADIC-MANAGEMENT-MIB)
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The Quantum (ADIC) Enterprise Level Tape Libraries connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.3764.1.1.200.20.80.110.1must return a value in the same subtree
Monitors
| Object Type | Discovered Properties | Collected Parameters |
|---|---|---|
| Enclosure (MS_HW_ENCLOSURE) |
|
|
| Fan (MS_HW_FAN) |
|
|
| Other Device (MS_HW_OTHERDEVICE) |
|
|
| Power Supply (MS_HW_POWERSUPPLY) |
|
|
| Robotic (MS_HW_ROBOTICS) |
|
|
| Tape Drive (MS_HW_TAPEDRIVE) |
|
|
| Temperature Sensor (MS_HW_TEMPERATURE) |
|
|
| Voltage Sensor (MS_HW_VOLTAGE) |
|
|