Back to the list of connectors
EMC Isilon Cluster (REST)
Connector file name: MS_HW_EMCIsilonREST.hdf
Description
This connector discovers the status of an EMC Isilon Storage Cluster, as well as the various environment sensors (temperatures, fans, power supplies, etc.). Requires EMC Isilon (v8) or later.
Target
Typical platform: EMC Isilon
Operating system: Storage System
Prerequisites
Relies on:
Technology and protocols: HTTP/REST
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The EMC Isilon Cluster (REST) connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:
- The HTTP Request below to the managed host succeeds:
- GET
/platform/3/cluster/version - The response body contains:
Isilon OneFS(regex)
Monitors
Object Type Discovered Properties Collected Parameters Enclosure (MS_HW_ENCLOSURE) - Additional Information 1
- Model
- Serial Number
- Type
- Vendor
- Status
Battery (MS_HW_BATTERY) - Status
Processor (MS_HW_CPU) - Model
- Status
Fan (MS_HW_FAN) - Alarm Threshold
- Warning Threshold
- Speed
Logical Disk, RAID (MS_HW_LOGICALDISK) - Additional Information 1
- Size
- Status
Network Card, FC Port (MS_HW_NETWORK) - Link Status
- Status
Physical Disk (MS_HW_PHYSICALDISK) - Model
- Serial Number
- Size
- Status
Power Supply (MS_HW_POWERSUPPLY) - Additional Information 1
- Status
Temperature Sensor (MS_HW_TEMPERATURE) - Alarm Threshold
- Warning Threshold
- Temperature
Voltage Sensor (MS_HW_VOLTAGE) - Lower Threshold
- Upper Threshold
- Voltage
- GET