Back to the list of connectors

Data Domain Storage Appliance (SNMP)

Connector file name: MS_HW_DataDomain.hdf

Description

This connector discovers the enclosure and the disks of Data Domain disk arrays as well as the various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.

Target

Typical platform: Data Domain

Operating system: Storage System

Prerequisites

Relies on: Data Domain SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Data Domain Storage Appliance (SNMP) connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.19746.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Type
  • Vendor
    Fan (MS_HW_FAN)
    • Additional Information 1
    • Fan Type/Location
    • Status
    Logical Disk, RAID (MS_HW_LOGICALDISK)
    • Size
    • Unallocated Space
    Physical Disk (MS_HW_PHYSICALDISK)
    • Model
    • Serial Number
    • Size
    • Status
    Power Supply (MS_HW_POWERSUPPLY)
    • Additional Information 1
    • Power Supply Type
    • Status
    Temperature Sensor (MS_HW_TEMPERATURE)
    • Additional Information 1
    • Sensor Type/Location
    • Warning Threshold
    • Temperature