## Hardware Memory Module

PATROL Class: **MS_HW_MEMORY** - Monitor Type: **MONITOR** - Monitor Category: **System**  
No CDM Class defined.  


Monitors a specific memory module and verifies if it is present and operating correctly.

### Attributes (Parameters)

| Name | PATROL Name | Units | Default Thresholds | Description |
| --- | --- | --- | --- | --- |
| Error Count | ErrorCount | errors |  ALARM if ≥ 1 errors | Number of errors detected by the memory module and then corrected. A steadily growing value means that the memory module is not reliable and that it could encounter errors that it is unable to correct, which means this could lead to a system crash. Value set by memoryColl. Type: Statistics |
| Predicted Failure | PredictedFailure | 0 = OK 1 = Failure Predicted |  WARN if = 1 (Failure Predicted) | A predicted failure is set by analyzing the trend of the number of detected/corrected errors (with the ECC technology). If predicted, replacement of the faulty memory module is highly recommended. Value set by memoryColl. Type: Availability |
| Present | Present | 0 = Missing 1 = Present |  ALARM if = 0 (Missing) | Availability of the memory module. Value set by memoryColl. Type: Availability |
| Status | Status | 0 = OK 1 = Degraded 2 = Failed |  WARN if = 1 (Degraded)  ALARM if = 2 (Failed) | Current status of the memory module. The Status parameter will raise an "on the fly" alert on servers that can dynamically handle failed memory modules or, most often, for modules that have been disabled by the BIOS upon reboot (the module is then flagged as missing). Value set by memoryColl. Type: Availability - Default graph |
| Status Information | StatusInformation | None | None | Additional (textual) information about the current status of the memory module. Value set by memoryColl. Type: Text |