SMcli Settings 
 | 
Enables you to configure the SMcli settings. 
 | 
Add a Connection to a Storage Subsystem 
 | 
Enables you to add a subsystem to the monitored environment. 
 | 
Reporting 
 | 
Generates activity reports for the monitored devices. 
 | 
Reporting > Subsystems Activity... 
 | 
Generates a report on the subsystems activity. 
 | 
Reporting > Controllers Activity... 
 | 
Generates a report on the controllers activity. 
 | 
Reporting > Logical Drives Activity... 
 | 
Generates a report on the logical drives activity. 
 | 
Reporting > Logical Drives Mapping Table... 
 | 
Generates a report listing mapped and unmapped logical drives. 
 | 
Reporting > Per Host Storage Allocation 
 | 
Generates a report on the volume of storage allocated to each monitored host. 
 | 
Reporting > Per LUN Storage Allocation 
 | 
Generates a report on the volume of storage allocated to each monitored LUN. 
 | 
Search WWN 
 | 
Enables you to find any component based on its complete or partial World Wide Name. 
 | 
KM Settings 
 | 
Displays all the command options for different monitoring settings. 
 | 
KM Settings > Java Settings 
 | 
Enables you to define which Java instance is to be used by the KM. 
 | 
KM Settings > Discovery Interval  
 | 
Enables you to customize the discovery cycle. By default, discovery is performed every hour. 
 | 
KM Settings > Polling Interval  
 | 
Enables you to customize the polling cycle. By default, the polling interval is done every 2 minutes. 
 | 
KM Settings > Alert Actions  
 | 
Enables you to select the Alert Actions (different methods of notification) to be executed by the KM when a parameter breaches its threshold. 
 | 
KM Settings > Additional Settings 
 | 
Enables you to perform additional settings such as restoring device monitoring and enabling/disabling debug mode. 
 | 
KM Settings > Additional Settings > Threshold Mechanism Selection 
 | 
Allows you to select the threshold mechanism: 
| • | Automatic (by default): the KM determines the mode of threshold management best suited to the system. The different modes are: |  
 | • | Tuning: the KM uses the internal PATROL mechanism to set thresholds |  
 | • | Event Management: the KM automatically sets thresholds through the Event Management |  
 | • | No thresholds: the KM does not set any thresholds and lets you specify them manually. |  
  | 
KM Settings > Additional Settings > Restore Monitoring  
 | 
Brings up the "Restore Monitoring" wizard to restore one or several objects after their monitoring has been stopped. 
 | 
KM Settings > Debug  
 | 
Activates or deactivates the debug mode. The debug Mode displays debug messages in the PATROL System Output Window or saves it in a file if you enter the file path. 
 | 
Trigger a KM Discovery  
 | 
Enables you to trigger a forced discovery and rediscover the devices of the monitored system. 
 | 
Reinitialize KM  
 | 
Triggers a complete re-initialization of the KM. Customized settings are lost unless specified otherwise in the Reinitialize wizard. 
 | 
About 
 | 