Studio File System

Home  Previous  Next

Attributes

Name

Description

Units

Default Alert Conditions

Attribute Type

Available Capacity*

Total capacity not consumed in the file system.
Value set by fileSystemColl.

Megabytes (MB)

Alarm ≤ 10

Statistics

Available Capacity Percentage*

Percentage of capacity not consumed in the file system.
Value set by fileSystemColl.

Percentage (%)

Warning ≤ 10

Alarm  ≤ 1

Statistics

Available Inodes Percentage

Percentage of available inodes on UNIX and Linux platforms.
Value set by fileSystemColl.

Percentage (%)

Warning ≤ 10

Alarm  ≤ 1

Statistics

Consumed Capacity Growth Percentage

Percentage of the capacity that is actually consumed per hour in the file system.
Value set by fileSystemColl.

Percentage per hour (%/h)

None

Statistics

Consumed Capacity Growth Speed

Speed at which the capacity is actually consumed in the file system.
Value set by fileSystemColl.

Megabytes per hour (MB/h)

None

Statistics

* Attributes marked with an asterisk are used by default when visualizing the corresponding monitor instance in TrueSight Operations Management.