Back to the list of connectors

HP Insight Management Agent - IDE Storage

Connector file name: MS_HW_CpqIDEDriveArray.hdf

This connector supersedes:

Description

This connector monitors the HP/Compaq IDE Drive Arrays by connecting to the Storage Management SNMP sub-agent of the HP Insight Manager agent.

Target

Typical platform: HP ProLiant

Operating systems: Microsoft Windows, Linux, HP Tru64, HP OpenVMS, Out-of-Band, Oracle Solaris

Prerequisites

Relies on: HP Insight Management Agents

Technology and protocols: SNMP

Connector Activation Criteria

The HP Insight Management Agent - IDE Storage connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.232.14.2.4.1.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Disk Controller (MS_HW_DISKCONTROLLER)
  • Firmware Version
  • Model
    Logical Disk, RAID (MS_HW_LOGICALDISK)
    • Additional Information 1
    • RAID Level
    • Size
    • Status
    Physical Disk (MS_HW_PHYSICALDISK)
    • Additional Information 1
    • Additional Information 2
    • Additional Information 3
    • Serial Number
    • Size
    • Vendor
    • Predicted Failure
    • Status