Dell EqualLogic PS Series

Connector file name: MS_HW_Equallogic.hdf

Description

Because multiple PS Systems can be managed by the same controller, the connector can discover multiple enclosures.

Target

Typical platform: Dell EqualLogic

Operating system: Storage System

Prerequisites

Relies on: Dell EqualLogic SNMP Agent (EQLGROUP-MIB)

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Dell EqualLogic PS Series connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.12740.2.1.11.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Additional Information 1
  • Model
  • Serial Number
  • Type
  • Vendor
    Disk Controller (MS_HW_DISKCONTROLLER)
    • Firmware Version
    • Model
    • Serial Number
      Battery (MS_HW_BATTERY)
      • Type
      • Status
      Fan (MS_HW_FAN)
      • Alarm Threshold
      • Fan Type/Location
      • Warning Threshold
      • Speed
      • Status
      Logical Disk, RAID (MS_HW_LOGICALDISK)
      • Logical Disk Type
      • Size
      • Status
      Physical Disk (MS_HW_PHYSICALDISK)
      • Additional Information 1
      • Firmware Version
      • Model
      • Serial Number
      • Size
      • Error Count
      • Status
      Power Supply (MS_HW_POWERSUPPLY)
      • Power Supply Type
      • Status
      Temperature Sensor (MS_HW_TEMPERATURE)
      • Alarm Threshold
      • Sensor Type/Location
      • Warning Threshold
      • Status
      • Temperature
      Keywords: