Back to the list of connectors

HP 3PAR Disk Array

Connector file name: MS_HW_HP3PAR.hdf

This connector supersedes:

Description

This connector discovers the enclosure and the disks of HP 3PAR disk arrays, as well as the storage pools. It will also discover and monitor the FC ports of the array and the various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.

Target

Typical platform: HP 3PAR

Operating system: Storage System

Prerequisites

Relies on: HP 3PAR Embedded SMI-S Provider

Technology and protocols: WBEM

Connector Activation Criteria

The HP 3PAR Disk Array connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • The WBEM query below to the managed host succeeds:
    • Namespace: root/tpd
    • WQL Query: SELECT Name FROM TPD_StorageSystem

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Additional Information 1
  • Additional Information 2
  • Additional Information 3
  • Firmware Version
  • Model
  • Serial Number
  • Type
  • Vendor
  • Status
Battery (MS_HW_BATTERY)
  • Additional Information 1
  • Additional Information 2
  • Status
Blade (MS_HW_BLADE)
  • Additional Information 1
  • Additional Information 2
  • Blade Model
  • Serial Number
  • Status
Processor (MS_HW_CPU)
  • Additional Information 1
  • Status
Fan (MS_HW_FAN)
  • Additional Information 1
  • Status
Logical Disk, RAID (MS_HW_LOGICALDISK)
  • Logical Disk Type
  • RAID Level
  • Size
  • Inclusion in Total Logical Disk Size
  • Status
Memory Module (MS_HW_MEMORY)
  • Additional Information 1
  • Model
  • Serial Number
  • Size
  • Vendor
  • Status
Network Card, FC Port (MS_HW_NETWORK)
  • Device Type
  • Physical Address
  • Physical Address Type
  • Status
Other Device (MS_HW_OTHERDEVICE)
  • Additional Information 1
  • Additional Information 2
  • Additional Information 3
  • Device Type
  • Status
Physical Disk (MS_HW_PHYSICALDISK)
  • Additional Information 1
  • Additional Information 2
  • Additional Information 3
  • Model
  • Serial Number
  • Size
  • Vendor
  • Status
Power Supply (MS_HW_POWERSUPPLY)
  • Additional Information 1
  • Additional Information 2
  • Additional Information 3
  • Status
Temperature Sensor (MS_HW_TEMPERATURE)
  • Alarm Threshold
  • Warning Threshold
  • Temperature
Voltage Sensor (MS_HW_VOLTAGE)
  • Lower Threshold
  • Upper Threshold
  • Voltage
Keywords: