Back to the list of connectors

HP Insight Management Agent - Server (WBEM)

Connector file name: MS_HW_HPInsightwbem.hdf

This connector is superseded by:

This connector supersedes:

Description

This connector provides hardware monitoring through the HP Insight Manager (Server Agent) which supports almost all HP ProLiant and Integrity servers under Windows and Linux, as well as Tru64 servers.

Target

Typical platform: HP ProLiant

Operating systems: Linux, Out-of-Band

Prerequisites

Relies on: HP Insight Management Agents (WBEM)

Technology and protocols: WBEM

Connector Activation Criteria

The HP Insight Management Agent - Server (WBEM) connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • Operating System is Linux or Out-of-Band
  • The WBEM query below to the managed host succeeds:
    • Namespace: root/hpq
    • WQL Query: SELECT Model FROM HP_ComputerSystemChassis
  • The WBEM query below to the managed host succeeds:
    • Namespace: root/hpq
    • WQL Query: SELECT DeviceID FROM HP_NumericSensor

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Model
  • Serial Number
  • Type
  • Vendor
  • Power Consumption
Processor (MS_HW_CPU)
  • Maximum Speed
  • Model
  • Vendor
  • Current Speed
  • Status
Fan (MS_HW_FAN)
  • Fan Type/Location
  • Status
Memory Module (MS_HW_MEMORY)
  • Serial Number
  • Size
  • Type
  • Status
Network Card, FC Port (MS_HW_NETWORK)
  • Additional Information 1
  • Logical Address
  • Logical Address Type
  • Model
  • Physical Address
  • Physical Address Type
  • Bandwidth Utilization
  • Error Count
  • Error Percent
  • Link Speed
  • Link Status
  • Received Bytes Rate
  • Received Packets Rate
  • Status
  • Transmitted Bytes Rate
  • Transmitted Packets Rate
Other Device (MS_HW_OTHERDEVICE)
  • Additional Label
  • Device Type
  • Status
Power Supply (MS_HW_POWERSUPPLY)
  • Power (Nominal)
  • Power Supply Type
  • Status
Temperature Sensor (MS_HW_TEMPERATURE)
  • Alarm Threshold
  • Sensor Type/Location
  • Warning Threshold
  • Status
  • Temperature
Keywords:
hardware hdf patrol connectors