Back to the list of connectors

HP P2000 G3 or Later (WBEM)

Connector file name: MS_HW_HPP2000WBEM.hdf

This connector supersedes:

Description

This connector discovers the Environmental, Physical Disk, Logical Disk, Management Network Cards and Fibre Ports on P2000 G3 later Series Filers through the Embedded SMI-S Provider

Target

Typical platform: HP StorageWorks P2000 G3

Operating system: Storage System

Prerequisites

Relies on: HP P2000 Management Card

Technology and protocols: WBEM

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The HP P2000 G3 or Later (WBEM) connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • The WBEM query below to the managed host succeeds:
    • Namespace: root/hpq
    • WQL Query: SELECT Name FROM HP_TopComputerSystem
  • The WBEM query below to the managed host succeeds:
    • Namespace: root/hpq
    • WQL Query: SELECT Tag FROM HP_TopComputerSystemChassis

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Additional Information 1
  • Model
  • Serial Number
  • Type
  • Vendor
  • Status
Fan (MS_HW_FAN)
    • Status
    Logical Disk, RAID (MS_HW_LOGICALDISK)
    • Size
    • Status
    Network Card, FC Port (MS_HW_NETWORK)
    • Physical Address
    • Physical Address Type
    • Link Status
    • Speed
    • Status
    Other Device (MS_HW_OTHERDEVICE)
    • Device Type
    • Status
    Physical Disk (MS_HW_PHYSICALDISK)
    • Additional Information 1
    • Model
    • Serial Number
    • Size
    • Type
    • Status
    Power Supply (MS_HW_POWERSUPPLY)
      • Status
      Temperature Sensor (MS_HW_TEMPERATURE)
        • Status
        Voltage Sensor (MS_HW_VOLTAGE)
          • Status
          Keywords:
          hardware hdf patrol connectors