Back to the list of connectors

Hitachi BladeSymphony Chassis

Connector file name: MS_HW_HitachiBladeSymphony.hdf

Description

This connector provides hardware monitoring for the Hitachi BladeSymphony Chassis racks through the Hitachi BladeSymphony Chassis Management Module

Target

Typical platform: Hitachi BladeSymphony

Operating system: Out-of-Band

Prerequisites

Relies on: Hitachi BladeSymphony Chassis Management Module

Technology and protocols: SNMP

Connector Activation Criteria

The Hitachi BladeSymphony Chassis connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.116.5.39.1.10 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Model
  • Serial Number
  • Type
  • Vendor
  • Power Consumption
Blade (MS_HW_BLADE)
  • Additional Information 1
  • Additional Information 2
  • Blade Model
  • Serial Number
  • Power State
  • Status
Fan (MS_HW_FAN)
  • Additional Information 1
  • Alarm Threshold
  • Fan Type/Location
  • Speed
  • Status
LED (MS_HW_LED)
  • Name
  • Status When Off
  • Status When On
  • Status
Other Device (MS_HW_OTHERDEVICE)
  • Additional Information 1
  • Additional Information 2
  • Additional Information 3
  • Additional Label
  • Device Type
  • Status
Power Supply (MS_HW_POWERSUPPLY)
  • Additional Information 1
  • Additional Information 2
  • Power Supply Type
  • Status
Temperature Sensor (MS_HW_TEMPERATURE)
  • Additional Information 1
  • Alarm Threshold
  • Status
  • Temperature
Keywords: