Back to the list of connectors

IBM DataPower (SNMP)

Connector file name: MS_HW_IBMDataPower.hdf

Description

This connector discovers the enclosure and the disks of IBM DataPower Appliances as well as the various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.

Target

Typical platform: IBM DataPower

Operating system: Out-of-Band

Prerequisites

Relies on: IBM DataPower SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The IBM DataPower (SNMP) connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.14685.3.1.100.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Model
  • Type
  • Vendor
    Fan (MS_HW_FAN)
    • Alarm Threshold
    • Speed
    Physical Disk (MS_HW_PHYSICALDISK)
    • Model
    • Vendor
    • Status
    Power Supply (MS_HW_POWERSUPPLY)
      • Status
      Temperature Sensor (MS_HW_TEMPERATURE)
      • Alarm Threshold
      • Warning Threshold
      • Temperature
      Voltage Sensor (MS_HW_VOLTAGE)
      • Lower Threshold
      • Upper Threshold
      • Voltage
      Keywords:
      hardware hdf patrol connectors