Back to the list of connectors

IBM FlashSystem 700/800

Connector file name: MS_HW_IBMFlash800.hdf

Description

This connector discovers the enclosure(s) and the disks of IBM FlashSystem 700/800s as well as the various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.

Target

Typical platform: IBM FlashSystem

Operating system: Storage System

Prerequisites

Relies on: IBM FlashSystem 700/800 SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The IBM FlashSystem 700/800 connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.8378.10.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Firmware Version
  • Model
  • Type
  • Status
Battery (MS_HW_BATTERY)
    • Status
    Fan (MS_HW_FAN)
      • Speed
      • Speed Percent
      • Status
      Network Card, FC Port (MS_HW_NETWORK)
      • Physical Address
      • Physical Address Type
      • Link Speed
      • Link Status
      Physical Disk (MS_HW_PHYSICALDISK)
      • Size
      • Status
      Power Supply (MS_HW_POWERSUPPLY)
        • Status
        Temperature Sensor (MS_HW_TEMPERATURE)
          • Status
          • Temperature
          Voltage Sensor (MS_HW_VOLTAGE)
            • Status
            Keywords:
            hardware hdf patrol connectors