Back to the list of connectors

Adaptec IOManager

Connector file name: MS_HW_IOManager.hdf

Description

This connector provides disk monitoring through the Adaptec IO Manager SNMP sub-agent which supports a few AAC-based Adaptec RAID controllers.

Target

Typical platform: Fujitsu-Siemens PRIMERGY

Operating systems: Microsoft Windows, Linux

Prerequisites

Relies on: Adaptec IOManager

Technology and protocols: SNMP

Connector Activation Criteria

The Adaptec IOManager connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.795.12.2.3.1.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Disk Controller (MS_HW_DISKCONTROLLER)
  • Model
  • Vendor
    Logical Disk, RAID (MS_HW_LOGICALDISK)
    • RAID Level
    • Size
    • Status
    Physical Disk (MS_HW_PHYSICALDISK)
    • Size
    • Vendor
    • Predicted Failure
    • Status
    Keywords:
    hardware hdf patrol connectors