Back to the list of connectors

Cisco MDS9000 Series (SSH)

Connector file name: MS_HW_CiscoTelnet.hdf

This connector supersedes:

Description

This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.).

Target

Typical platform: Cisco SAN

Operating system: Storage System

Prerequisites

Leverages: Commands on the Cisco Bay Controller

Technology and protocols: SSH

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Cisco MDS9000 Series (SSH) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • SSH is enabled on the monitored host
  • The monitored host must send #
  • The connector sends exit[Return]logout[Return]quit[Return]
  • The captured output contains Cisco (regex)

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Model
  • Serial Number
  • Type
  • Vendor
  • Power Consumption
Blade (MS_HW_BLADE)
  • Blade Model
  • Blade Name
  • Status
Fan (MS_HW_FAN)
    • Status
    Network Card, FC Port (MS_HW_NETWORK)
    • Device Type
    • Physical Address
    • Physical Address Type
    • Remote Physical Address
    • Remote Physical Address Type
    • Bandwidth Utilization
    • Duplex Mode
    • Error Percent
    • Link Speed
    • Link Status
    • Received Bytes Rate
    • Received Packets Rate
    • Status
    • Transmitted Bytes Rate
    • Transmitted Packets Rate
    • Zero Buffer Credit Percent
    Other Device (MS_HW_OTHERDEVICE)
    • Device Type
    • Status
    Power Supply (MS_HW_POWERSUPPLY)
      • Status
      Temperature Sensor (MS_HW_TEMPERATURE)
      • Alarm Threshold
      • Warning Threshold
      • Status
      • Temperature
      Keywords: