Back to the list of connectors

Data Domain Storage Appliance (SNMP)

Connector file name: MS_HW_DataDomain.hdf

Description

This connector discovers the enclosure and the disks of Data Domain disk arrays as well as the various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.

Target

Typical platform: Data Domain

Operating system: Storage System

Prerequisites

Leverages: Data Domain SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Data Domain Storage Appliance (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.19746.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Type
  • Vendor
    Battery (MS_HW_BATTERY)
      • Charge
      • Status
      Fan (MS_HW_FAN)
      • Fan Type/Location
      • Status
      Logical Disk, RAID (MS_HW_LOGICALDISK)
      • Size
      • Unallocated Space
      Physical Disk (MS_HW_PHYSICALDISK)
      • Model
      • Serial Number
      • Size
      • Status
      Power Supply (MS_HW_POWERSUPPLY)
      • Power Supply Type
      • Status
      Temperature Sensor (MS_HW_TEMPERATURE)
      • Sensor Type/Location
      • Warning Threshold
      • Temperature
      Keywords:
      hardware hdf patrol connectors