Back to the list of connectors
Hitachi HDS AMS/HUS (SNM2 CLI on Linux)
Connector file name: MS_HW_HitachiSNM2CLILinux.hdf
Description
This connector discovers the status of Hitachi AMS/HUS's Processors, CSW, Cache, SM, Power Supplies, Batteries, Fans, Physical Disks and Environment.
Target
Typical platforms: Hitachi AMS, Hitachi HUS
Operating system: Storage System
Prerequisites
Leverages: Hitachi SNM2 CLI
Technology and protocols: System Commands
Connector Activation Criteria
The Hitachi HDS AMS/HUS (SNM2 CLI on Linux) connector must be selected manually, and its status will be reported as OK if all the below criteria are met:
- The command below succeeds on the agent host
- Command:
uname
- Output contains:
Linux
(regex)
- Command:
- The command below succeeds on the agent host
- Command:
if [ -n "$STONAVM_HOME" ]; then echo STONAVM_HOME Defined; fi
- Output contains:
STONAVM_HOME Defined
(regex)
- Command:
- The command below succeeds on the agent host
- Command:
if [ -n "$LD_LIBRARY_PATH" ]; then echo LD_LIBRARY_PATH Defined; fi
- Output contains:
LD_LIBRARY_PATH Defined
(regex)
- Command:
- The command below succeeds on the agent host
- Command:
export STONAVM_RSP_PASS=on;echo %{PASSWORD}>$STONAVM_HOME/MS_HW_pwdfile;$STONAVM_HOME/auaccountenv -set -uid %{USERNAME} -passwdfile $STONAVM_HOME/MS_HW_pwdfile
- Output contains:
The account information has been set successfully
(regex)
- Command:
Monitors
Object Type | Discovered Properties | Collected Parameters |
---|---|---|
Enclosure (MS_HW_ENCLOSURE) |
|
|
Battery (MS_HW_BATTERY) |
|
|
Fan (MS_HW_FAN) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK) |
|
|
Memory Module (MS_HW_MEMORY) |
|
|
Network Card, FC Port (MS_HW_NETWORK) |
|
|
Other Device (MS_HW_OTHERDEVICE) |
|
|
Physical Disk (MS_HW_PHYSICALDISK) |
|
|
Power Supply (MS_HW_POWERSUPPLY) |
|
|
Keywords:
hardware hdf patrol connectors
hardware hdf patrol connectors