Back to the list of connectors

Intel Modular Server

Connector file name: MS_HW_IntelModularServer.hdf

Description

This connector provides hardware monitoring through the Intel Modular Server Chassis Managament Module's SNMP Agents.

Target

Typical platform: Intel Modular

Operating system: Out-of-Band

Prerequisites

Leverages: Intel Server Manager 8 SNMP Agents

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Intel Modular Server connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.343.2.19.1.2.10.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Type
  • Vendor
    Disk Controller (MS_HW_DISKCONTROLLER)
    • Model
    • Controller Status
    Blade (MS_HW_BLADE)
      • Status
      Fan (MS_HW_FAN)
      • Alarm Threshold
      • Fan Type/Location
      • Speed
      • Status
      Network Card, FC Port (MS_HW_NETWORK)
      • Physical Address
      • Physical Address Type
      • Bandwidth Utilization
      • Error Percent
      • Link Speed
      • Link Status
      • Received Bytes Rate
      • Status
      • Transmitted Bytes Rate
      Other Device (MS_HW_OTHERDEVICE)
      • Device Type
      • Status
      Physical Disk (MS_HW_PHYSICALDISK)
      • Additional Information 1
      • Firmware Version
      • Serial Number
      • Size
      • Vendor
      • Predicted Failure
      • Status
      Power Supply (MS_HW_POWERSUPPLY)
        • Status
        Keywords:
        hardware hdf patrol connectors