Back to the list of connectors

Quanta Rack Mount Server Unit

Connector file name: MS_HW_Quanta.hdf

Description

This connector provides the hardware monitoring of the Quanta Rack Mount Server Unit through the SNMP Agent of Quanta System Manager. As Quanta System Manager is an application exposing the data about other systems, this connector needs to be configured for a separate "Management Card/Chip" host, even if Quanta System Manager is installed on the same system as the PATROL Agent.

Target

Typical platform: Quanta Server

Operating system: Out-of-Band

Prerequisites

Leverages: Quanta System Manager SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Quanta Rack Mount Server Unit connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.7244.1.2.1.3.1.1.3 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Additional Information 1
  • BIOS Version
  • Serial Number
  • Type
  • Vendor
  • Status
Processor (MS_HW_CPU)
  • Maximum Speed
  • Model
  • Vendor
  • Current Speed
  • Status
Fan (MS_HW_FAN)
  • Alarm Threshold
  • Warning Threshold
  • Speed
  • Status
Memory Module (MS_HW_MEMORY)
  • Additional Information 1
  • Additional Information 3
  • Size
  • Type
  • Status
Power Supply (MS_HW_POWERSUPPLY)
    • Status
    Temperature Sensor (MS_HW_TEMPERATURE)
    • Alarm Threshold
    • Warning Threshold
    • Status
    • Temperature
    Voltage Sensor (MS_HW_VOLTAGE)
    • Lower Threshold
    • Upper Threshold
    • Status
    • Voltage
    Keywords:
    hardware hdf patrol connectors