Back to the list of connectors

Oracle/Sun Xsigo Switch

Connector file name: MS_HW_SunXsigoSwitch.hdf

This connector supersedes:

Description

This connector discovers the enclosure and ports of the switch as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol.

Target

Typical platform: Oracle/Sun Xsigo

Operating systems: Storage System, Network Device

Prerequisites

Leverages: Sun Xsigo SNMP Agent

Technology and protocols: SNMP

Connector Activation Criteria

The Oracle/Sun Xsigo Switch connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.24440.3.1.1.1 must return a value in the same subtree

Monitors

Object Type Discovered Properties Collected Parameters
Enclosure (MS_HW_ENCLOSURE)
  • Additional Information 1
  • BIOS Version
  • Model
  • Serial Number
  • Type
  • Vendor
  • Status
Fan (MS_HW_FAN)
  • Warning Threshold
  • Speed
  • Status
Network Card, FC Port (MS_HW_NETWORK)
  • Device Type
  • Physical Address
  • Physical Address Type
  • Bandwidth Utilization
  • Error Count
  • Link Speed
  • Link Status
  • Received Bytes Rate
  • Received Packets Rate
  • Status
  • Transmitted Bytes Rate
  • Transmitted Packets Rate
Other Device (MS_HW_OTHERDEVICE)
  • Additional Information 1
  • Additional Information 2
  • Additional Label
  • Device Type
  • Status
Power Supply (MS_HW_POWERSUPPLY)
    • Status
    Temperature Sensor (MS_HW_TEMPERATURE)
    • Alarm Threshold
    • Temperature
    Keywords:
    hardware hdf patrol connectors