Back to the list of classes

Hardware Enclosure

PATROL Class: MS_HW_ENCLOSURE - Monitor Type: MONITOR - Monitor Category: System
CDM Class: BMC_ComputerSystem -- Instances of this monitor will be represented as devices in TrueSight Operations Management

Monitors a hardware enclosure, such as a computer's main chassis, external disk arrays or blade enclosures.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Intrusion Status IntrusionStatus 0 = OK
2 = Intrusion Detected
None

Monitors the intrusion status of the enclosure. If the enclosure is open or not properly closed, it is set to Intrusion Detected.

Value set by enclosureColl.

Type: Availability

Power Consumption PowerConsumption Watts None

This parameter reports the electricity consumption.

Value set by enclosureColl.

Type: Statistics - Default graph

Present Present 0 = Missing
1 = Present

 ALARM
if = 0 (Missing)

Indicates whether the enclosure is found or not.

Value set by enclosureColl.

Type: Availability

Status Status 0 = OK
1 = Degraded
2 = Failed

 WARN
if = 1 (Degraded)

 ALARM
if = 2 (Failed)

Current status of the enclosure.

Value set by enclosureColl.

Type: Availability

Status Information StatusInformation None None

Additional (textual) information about the current status of the enclosure.

Value set by enclosureColl.

Type: Text

Infoboxes (PATROL Console Only)

Name Description
PATROL ID PATROL internal identifier for the enclosure instance.
Enclosure Information ......................................................................................................................................................................................................................................
Manufacturer Name of the enclosure/chassis manufacturer.
Model Enclosure model details.
Type Details about the type of enclosure/chassis.
Serial Number Serial number of the enclosure/chassis.
BIOS Version Details about the BIOS version.
Device ID ID of the monitored enclosure as communicated by the instrumentation layer.
Identifying Information Any additional information available for the enclosure.
Connector Information ......................................................................................................................................................................................................................................
Connector Display Name Display name of the connector currently used to monitor the enclosure.
Connector ID PATROL ID of the connector currently used to monitor the enclosure.
Connector File Name File name of the connector currently used to monitor the enclosure.
Connector Version Version number of the connector.
Connector Date Connector build date.
Menu Command Description
Instant Hardware Health Report Displays a text box recapitulating miscellaneous information regarding the monitored device (properties of the object, its parameters, thresholds, etc.).
Acknowledge IntrusionStatus Alert Allows you to acknowledge and clear the alert triggered by the IntrusionStatus parameter.
Pause Monitoring Pauses the monitoring of the selected enclosure.
Resume Monitoring Resumes the monitoring of the selected enclosure.
Remove Removes the enclosure from the monitoring environment.
Refresh Parameters Refreshes all enclosure parameters.
Keywords: