P1051 - IBM Director 5.20.x on Windows
Feb 11, 2008Download File
Patch content
Set of connectors dedicated to the monitoring of IBM xSeries servers running Windows through the IBM Director Agent version 5.20.x
Should you install this patch?
Apply this patch if you are using Hardware Sentry on IBM xSeries servers running Windows with the version 5.20 of the IBM Director Agent
What does it fix?
The version 5.20 of the IBM Director Agent was not fully supported by Hardware Sentry 1.4.00. Disks (controllers, physical disks and RAIDs) were notably neither discovered nor monitored.
How to install the patch?
Install the following files in the %PATROL_HOME%\lib\MS_HW_hdf directory of the managed server:
- MS_HW_Director5NT.hdf
- MS_HW_Director52AdaptecNT.hdf
- MS_HW_Director52LSINT.hdf
- MS_HW_Director52NT.hdf
Reinitialize the KM for the new connectors to be taken into account ([Right-click] on the main Hardware Sentry icon > [KM Commands] > [Reinitialize...]).