Patches

P1259: Sensors not properly handled by the Sun ILOM Connector

Jan 17, 2012
Patch for BMC Performance Manager Express for Hardware - Version(s) 2.7.00, 2.7.03, 2.7.05, 2.7.13, 2.7.17, 2.7.26

This patch is replaced with !

 Download

Patch content

Connector file for monitoring Sun Servers via their ILOM systems.

Should you install this patch?

Apply this patch if you are getting Invalid OID error messages when monitoring Sun Servers using the ILOM connector.

What does it fix?

This patch fixes an issue occurring when monitoring Sun Servers via their ILOM systems. Invalid OID error messages were raised as the connector did not handle situations where sensors had either a numerical or a discrete value. The issue did not occur when the sensor had both a numerical and a discrete value.

How to install the patch?

Copy the following file to %RSM_HOME%\RSMxx\SEN_HW\hdf_27xx\ on each RSM:

  • MS_HW_SunILOMSNMP.hdf