Patches

P1562: Hitachi HDS AMS/HUS Monitoring HSNM2 CLI Improved Reliability

Sep 5, 2014
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.00, 1.8.01, 1.8.02, 1.9.00

This patch is replaced with !

 Download

Patch content

Connectors for Hitachi HDS AMS/HUS Storage Systems

Should you install this patch?

Install this patch if you are getting failed collects and missing devices when using the Hitachi HDS AMS/HUS Storage Systems connector.

What does it fix?

The execution of all commands is now fully serialized to prevent conflicts. All temporary files used by the batch files/shell scripts now use randomized file names to prevent file locks and missing files.

How to install the patch?

  1. Copy the following files to the $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_HitachiSNM2CLILinux.hdf
    • MS_HW_HitachiSNM2CLINT.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect.
  3. Nothing needs to be installed on Console systems.