Patches

P1738: No Network Statistics for IBM AIX Servers SEA Adapters

March 24, 2016
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.01, 1.8.02, 1.9.00, 1.9.50

This patch is replaced with !

 Download

Patch content

Connector for "IBM AIX - Common"

Should you install this patch?

Install this patch if the virtual ports that are part of SEA Virtual Adapters have no statistics.

What does it fix?

Improves SEA Virtual Adapters monitoring to include statistics and link status for virtual ports.

How to install the patch?

  1. Copy the following file to the %PATROL_HOME%\lib\MS_HW_hdf or the $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_IBMAIX.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect. Nothing needs to be installed on console systems.