P1747: VMWare ESX - Single Non-Global Memory Module Discovered

April 22, 2016
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.01, 1.8.02, 1.9.00, 1.9.50

This patch is replaced with !

 Download

Patch content

  • Connector for VMware ESX 4 or later versions
  • Connector for VMware ESX 3 servers

Should you install this patch?

Install this patch if you are only seeing a single non-global memory module.

What does it fix?

Only one memory module was detected when the component ID was the same for all. To solve this issue, the patched connector will now use the device ID to identify memory modules.

How to install the patch?

  1. Copy the following files to the %PATROL_HOME%\lib\MS_HW_hdf or $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_VMwareESX4i.hdf
    • MS_HW_VMwareESXi.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect. Nothing needs to be installed on Console systems.