P1749: EMC Uemcli and EMC Navisphere CLI Conflict and Unbound Disks

April 22, 2016
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.01, 1.8.02, 1.9.00, 1.9.50

This patch is replaced with !

 Download

Patch content

Connectors for EMC CLARiiON, VNX and VNXe storage systems

Should you install this patch?

Install this patch if you have Uemcli and Navisphere CLI installed on the same server or if you have unbound disks.

What does it fix?

This patch:

  • prevents both UemCli and Navisphere from activating for the storage system.
  • recognizes the unbound status for the Navisphere physical disks

How to install the patch?

  1. Copy the following files to the %PATROL_HOME%\lib\MS_HW_hdf or $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_EMCuemcli.hdf
    • MS_HW_EMCNavisphereCLI.hdf