Volume

Home  Previous  Next

Parameters

Name

Description

Unit

Default Alert Conditions

CI_ID

Identifier of the configuration item (SAN:XXX RAIDROUP:XXX VOLUME:XXX).

n/a

n/a

Consumed Capacity Percentage

Percentage of the capacity that is actually consumed in the volume.

Percentage (%)

n/a

Consumed Capacity

Total size of the space actually allocated or reserved.

Gigabytes (GB)

n/a

Current Controller **

Controller currently associated to the volume.

n/a

n/a

Default Owning Controller **

Default controller if volumes are configured to use multiple controllers. The current controller can be different from the default one, e.g. if there’s a faulty controller.

n/a

n/a

Disk Time Utilization Baselining KPI **

Percentage of disk time utilization.

Percentage (%)

Warning = 90 % (for 5 consecutive collects)

Host Visible Capacity

Amount of capacity exposed to the host (i.e. subscribed capacity).

Gigabytes (GB)

n/a

Hosts

List of the Hosts to which the volume is attached.

n/a

n/a

Mapped

Indicates if the volume is linked to a Host.

(0 = Not Mapped; 1 = Mapped)

n/a

MetaTokenID

Identifier of the instance (naa:volume NAA ID). This identifier is required to ensure the instance is properly interpreted by BMC TrueSight Operations Management.

n/a

n/a

Operation Rate

Total number of operations per second.

 

Operations/s

n/a

Paths *

List of the paths to the ports to which the volume is attached.

n/a

n/a

RAID Level

Raid level of the volume.

n/a

n/a

Read Byte Rate Baselining KPI

Bytes read per second to the array since the last collect.

Megabytes per seconds (MB/s)

n/a

Read Bytes

Count of data read (Accumulated parameter-type).

Gigabytes (GB)

n/a

Read Operation Rate

Number of read operations per second.

Operations/s

n/a

Response Time Baselining KPI

Average response time for all operations.

Milliseconds (ms)

Warning = 10 (for 2 consecutive collects)

Storage Group

Name of the storage group associated to the volume.

n/a

n/a

Storage Pool

Name of the associated storage pool.

n/a

n/a

Time Since Last Activity

Number of days since any activity occurred on the volume.

Days

n/a

Transfer Byte Rate

Total bytes transferred per second (sent and received).

Megabytes per seconds (MB/s)

n/a

Transfer Bytes

Count of data transferred (Accumulated parameter-type).

Gigabytes (GB)

n/a

Volume Attributes

Description of the Storage Volume attributes.

n/a

n/a

Write Byte Rate Baselining KPI

Bytes written per second to the array since the last collect.

Megabytes per seconds (MB/s)

n/a

Write Bytes

Count of data written (Accumulated parameter-type).

Gigabytes (GB)

n/a

Write Operation Rate

Number of write operations per second.

Operations/s

 

WWN

Contains the WWN corresponding to this device, if applicable or known.

n/a

n/a

* Parameter not available on CLARiiON devices

** Parameters not available on Symmetrix Vmax devices.