Release Notes for v2.1.02 |
|
|
What's New •Support for EMC SMI-S provider v8.0.3. •Support for EMC NAS 8.1.0.
Changes and Improvements •The RAID Level trace in log files has been improved. •The CI_ID and MetaTokenID parameters were added to the following application classes, to allow users to populate the BPPM/TSIM Service cell with CIs and relationships: ▪Disk Array ▪CIFS Server ▪Controller ▪Data Mover ▪Control Station ▪DM Ethernet Port ▪Disk Group ▪EMC SMI-S Provider ▪EMC SMI-S Provider (Managed Array) ▪Ethernet Port ▪Fiber Port ▪File System ▪NFS Server, ▪Physical Disk ▪Power Supply ▪Storage Pool ▪Volume application classes •Only the CI_ID parameter was added to the Disk Array, Filer, Fan application classes. Fixed Issues •The Storage Pool parameter for the Volume application class is now collected for all volumes. •The Host WWN reported for volumes is now properly formatted and displayed. •The data gap that occurred after the discovery for the Disk Time Utilization and the Response Time parameters (CLARiiON and VNX physical disks only) has been fixed. Parameters are now accurately reported. Known Issues •Because the computation methods used by the EMC SMI-S provider differ between versions 4 and 8, the following parameters will not return the same value: ▪Consumed Capacity ( Volume | Storage Pool (Symmetrix) | Disk Group) ▪Consumed Capacity Percentage ( Volume | | Storage Pool (Symmetrix) | Disk Group) ▪Capacity (Disk Group | Disk Array) ▪Available Capacity ( Disk Array ) ▪Size ( Disk Group ) |