TrueSight Operations Management - Veritas NetBackup Monitoring

Release Notes v3.0.00

Home  Previous  Next

What's New

The product Symantec NetBackup Monitoring was renamed Veritas NetBackup Monitoring.
NBU-588 - Veritas NetBackup Monitoring supports Veritas NetBackup v7.7.
NBU-23 , NBU-216, NBU-607 - With the introduction of remote monitoring:
All NetBackup servers and appliances are supported
Media servers can be monitored from the master server
Monitoring can be blocked from the remote node.

Changes and Improvements

NBU-581 - Performance has been improved to support multiple remote nodes.
NBU-623 - The KM Status report file is now saved in the Temporary directory.
The Exec Time type of attributes are now activated by default.

Fixed Issues

NBU-564 - Child jobs were not created under the parent job when their policy client was different. To solve this issue, the parent job is now identified through its ID, type, and policy.
NBU-589  - Debug mode could not be enabled from CMA.
NBU-601 - Setup failed when the media server log path was not found.

Known Issue

NBU-565 - If an older version of the product has been previously imported into the repository, the old product name "Symantec NetBackup" will appear in the Monitoring Solution pull-down list when creating a new policy. To solve this issue:
1.Open the solution_list.xml file stored in %BMC_PROACTIVENET_HOME% \pproxy\depot_directory\bmc_products
2.Locate the following line: <product key="nbu">Symantec NetBackup</product>
3.Replace Symantec NetBackup with Veritas NetBackup
4.Remove the monitoring solution from the repository
5.Upload the monitoring solution package.