Dell Compellent Controller

Home  Previous  Next

Attributes

Name

Description

Units

Default Alert Conditions

Attribute Type

Consumed Memory Percentage*

Percentage of used memory.

Percentage (%)

Warning ≥ 80%

Alarm ≥ 90%

Statistics

Processor Utilization*

Utilization percentage of processor time.

Percentage (%)

Warning ≥ 80%

Alarm ≥ 90%

Statistics

Read Byte Rate

Read data traffic through the controller.

Megabytes per second (MB/s)

None

Statistics

Read Operation Rate

Total number of read operations per second.

Operations/s

None

Statistics

Read Response Time

Average response time for read operations.

Milliseconds (ms)

Warning ≥ 30 ms

Alarm ≥ 100 ms

Response Time

Response Time KPI

Average response time for all operations.

Milliseconds (ms)

Warning ≥ 30 ms

Alarm ≥ 100 ms

Response Time

Status

Status of the controller.

{0 = OK; 1 = Degraded; 2 = Failed}

Warning = 1
Alarm = 2

Availability

Transfer Byte Rate KPI

Read and written data traffic.

Megabytes per second (MB/s)

None

Statistics

Transfer Bytes

Amount of read and written data since the last collect.

Gigabytes (GB)

None

Statistics

Write Byte Rate

Amount of read and written data since the last collect.

Megabytes per second (MB/s)

None

Statistics

Write Operation Rate

Total number of write operations per second.

Operations/s

None

Statistics

Write Response Time

Average response time for write operations.

Milliseconds (ms)

Warning ≥ 30 ms

Alarm ≥ 100 ms

Response Time

* Attributes marked with an asterisk are used by default when visualizing the corresponding instance in TrueSight OM.