Dell Compellent Disk

Home  Previous  Next

Attributes

Name

Description

Units

Default Alert Conditions

Attribute Type

Present

Indicates whether the device is present or not since the last collect.

{0 = No; 1 = Yes}

Alarm = 0

Availability

Read Byte Rate

Data traffic read on the disk.

Megabytes per second (MB/s)

None

Statistics

Read Error Count

Number of read errors on the disk.

errors

None

Statistics

Read Operation Rate

Total number of read operations per second.

operations/s

None

Statistics

Read Response Time

Average response time for read operations.

Milliseconds (ms)

Warning ≥ 30 ms

Alarm ≥ 100 ms

Response Time

Response Time*

Average response time for all operations.

Milliseconds (ms)

Warning ≥ 30 ms

Alarm ≥ 100 ms

Response Time

Status

Status of the disk (combination of the disk status and the disk health).

{0 = OK; 1 = Degraded; 2 = Failed}

Warning = 1
Alarm = 2

Availability

Transfer Byte Rate *

Read and written data traffic.

Megabytes per second (MB/s)

None

Statistics

Write Byte Rate

Data traffic written on the disk.

Megabytes per second (MB/s)

None

Statistics

Write Error Count

Number of write errors on the disk.

Errors

None

Statistics

Write Operation Rate

Total number of write operations per second.

Operations/s

None

Statistics

Write Response Time

Average response time for write operations.

Milliseconds (ms)

Warning ≥ 30 ms

Alarm ≥ 100 ms

Response Time

* Attributes marked with an asterisk are used by default when visualizing the corresponding instance in TrueSight OM.