Fibre Alliance SNMP Agent (Switches)
Connector file name: MS_HW_FibreAllianceSwitch.hdf
This connector is superseded by:
Description
This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol and supports the Fibre Alliance MIB (FCMGMT-MIB).
Target
Typical platform: Any SAN switch
Operating system: Storage System
Prerequisites
Relies on: Fibre Alliance SNMP Agent (FCMGMT-MIB)
Technology and protocols: SNMP
Connector Activation Criteria
The Fibre Alliance SNMP Agent (Switches) connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:
- An SNMP Get-Next on the OID
1.3.6.1.3.94.1.6.1.3must return a value in the same subtree and contains\(^4$\)\|\(^14$\)(regex)
Monitors
| Object Type | Discovered Properties | Collected Parameters |
|---|---|---|
| Enclosure (MS_HW_ENCLOSURE) |
|
|
| Fan (MS_HW_FAN) |
|
|
| Network Card, FC Port (MS_HW_NETWORK) |
|
|
| Power Supply (MS_HW_POWERSUPPLY) |
|
|
| Temperature Sensor (MS_HW_TEMPERATURE) |
|
|