Back to the list of connectors
SMI-S Compliant SAN Switches
Connector file name: MS_HW_SMISSwitch.hdf
This connector is superseded by:
Description
This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant switches only.
Target
Typical platform: Any SMI-S compliant SAN switch
Operating system: Storage System
Prerequisites
Relies on: SMI-S Agent provided by the switch vendor
Technology and protocols: WBEM
Connector Activation Criteria
The SMI-S Compliant SAN Switches connector will be automatically activated, and its status will be reported as OK if all of the criteria below are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
Automatic - WQL Query:
SELECT Dedicated FROM CIM_ComputerSystem - Result contains:
^5|;*$(regex)
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
Automatic - WQL Query:
SELECT PortType FROM CIM_FCPort - Result contains:
^\(14\)\|\(15\)\|\(16\)\|\(17\)\|\(18\);$(regex)
- Namespace:
Monitors
| Object Type | Discovered Properties | Collected Parameters |
|---|---|---|
| Enclosure (MS_HW_ENCLOSURE) |
|
|
| Fan (MS_HW_FAN) |
|
|
| Network Card, FC Port (MS_HW_NETWORK) |
|
|
| Other Device (MS_HW_OTHERDEVICE) |
|
|
| Power Supply (MS_HW_POWERSUPPLY) |
|
|
| Temperature Sensor (MS_HW_TEMPERATURE) |
|
|