What's New

Dell Compellent KM for PATROL requires Java 1.8.00 or higher to perform properly.
A new configuration variable (automaticReinitialization) is now available to trigger a re-initialization of the KM.
A new configuration variable (disableMissingDeviceDetection) is now available to disable the missing device detection mechanism of Dell Compellent KM for PATROL .

Changes and Improvements

The conversion method used to calculate units for some duration-based parameters, such as ReadResponseTime, WriteResponseTime, ResponseTime, etc., has been improved to report accurately on the actual collected data.
The MetaEntityType infobox parameter has been added on the SEN_CMPL_STORAGECENTER application class to report on the system model. This parameter is updated upon each discovery cycle.
The iQN (iSCSI Qualified Name) is now handled for host mappings. When available, IQNs are displayed in the Initiator Groups' field of LUNs' infoboxes and in the WWN column of the LUNs Mapping Table.

Fixed Issues

The Acknowledge Error Count Alerts and Reset KM Command was not operating properly.
Monitored Storage Centers' status remained ONLINE even when the Enterprise Manager stopped.