NetApp Data ONTAP ETL for BMC TrueSight Capacity Optimization

Release Notes for v4.1.00

Home  Previous  Next

What's New

The parameters collection can now be performed at different rates to maintain a suitable refresh rate of the parameters and scale large environments. The following specific polling cycles per devices have been implemented:
File, Cluster, vFilers, Vservers, Controllers, Nodes, and Ports parameters are collected at every run
Aggregates and Disks parameters are collected once per hour
Shares, Volumes (and Host information) parameters are collected once per day

Changes and Improvements

Code robustness has been improved.
Object discovery is performed once per day instead of once per hour to improve the monitoring performance on large environments.
The SQLite store was replaced by a binary files store to avoid performance issues.
The service activity trace in service log files (also displayed in the log screen of the ETL tasks section) has been improved. The service loading is now logged in a serviceLoading.log dedicated file.
The discovery or the collect of metrics is automatically interrupted when the time dedicated to these processes exceeds 3 times the configured service’s period.
The data collection is now also available for volumes attached to a secondary controller.

Fixed Issues

An error occurred when populating Run History on BCO 9.5.01 or higher.
The Cache mechanism is now operational to avoid multiple requests from the NetApp Client.
The BYCONT_PROCESSOR_UTIL metric was not properly calculated for controllers and vFilers.