TrueSight Operations Management - NetApp Storage Monitoring

Release Notes v3.2.07

Home  Previous  Next

Fixed Issues

SENNA-2145: All the hardware components were detected as not present when the Shelf ID or Shelf Channel ID only contained one character.
The following issues occurred in 7-mode:
SENNA-2165: The partner controller (NetApp Controller) and its sub-objects (NetApp Host Adapter, NetApp Ethernet Port, NetApp FC Port, NetApp Processor, NetApp CIFS, NetApp iSCSI, NetApp NDMP and NetApp NFS) were not discovered.
SENNA-2165: Aggregates (NetApp Aggregate) and LUNs (NetApp LUN) were a replication of the first controller.
SENNA-2172: vFilers, Volumes and Quotas were not properly discovered when the multistore license was not available on the primary controller and when the Partner Hostname was used to configure the connection to the NetApp Filer.
SENNA-2184: An exception could occur when the partner controller was properly discovered upon a first discovery, but not upon the next one.

Known Issue

SENNA-2146: Duplicate hardware instances are created in the TrueSight console.