Back to the list of connectors
Brocade SAN Switch
Description
This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol and supports the Brocade MIB (fcSwitch-MIB).
Connector ID: BrocadeSwitch
This connector is superseded by:
This connector supersedes:
Target
Typical platform: Brocade SAN
Operating system: Storage System
Prerequisites
Leverages: Brocade SNMP Agent (fcSwitch)
Technology and protocols: SNMP
Examples
CLI
hws HOSTNAME -t storage -f BrocadeSwitch --snmp v2c --community publichws-config.yaml
hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ BrocadeSwitch ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secureConnector Activation Criteria
The Brocade SAN Switch connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID 1.3.6.1.4.1.1588.2.1.1.1.1must return a value in the same subtree
Metrics
| Type | Collected Metrics | Specific Attributes (Labels) | 
|---|---|---|
| Enclosure | 
 | 
 | 
| Fan | 
 | 
 | 
| Network Card, FC Port | 
 | 
 | 
| Other Device | 
 | 
 | 
| Power Supply | 
 | 
 | 
| Temperature Sensor | 
 | 
 | 