Back to the list of connectors
Dell iDRAC - Server
Description
This connector provides hardware monitoring through Dell's iDRAC Management Card for Dell servers with iDRAC7 or later.
Connector ID: DelliDRACServer
This connector is superseded by:
Target
Typical platform: Dell PowerEdge
Operating system: Out-of-Band
Prerequisites
Leverages: Dell iDRAC Management Card (iDRAC7 or Later)
Technology and protocols: SNMP
Examples
CLI
hws HOSTNAME -t management -f DelliDRACServer --snmp v2c --community publichws-config.yaml
hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ DelliDRACServer ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secureConnector Activation Criteria
The Dell iDRAC - Server connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID 1.3.6.1.4.1.674.10892.5.4must return a value in the same subtree
Metrics
| Type | Collected Metrics | Specific Attributes (Labels) | 
|---|---|---|
| Enclosure | 
 | 
 | 
| Battery | 
 | 
 | 
| Processor | 
 | 
 | 
| Fan | 
 | 
 | 
| Memory Module | 
 | 
 | 
| Network Card, FC Port | 
 | 
 | 
| Other Device | 
 |  | 
| Power Supply | 
 | 
 | 
| Temperature Sensor | 
 | 
 | 
| Voltage Sensor | 
 | 
 | 